Susol VCB

Features

Features

  • - Rated short-circuit withstand characteristics : 3sec
  • - Rated operating sequence : O-0.3s-CO-15s-CO
  • - Type test level : M2, E2(List1), C2
  • - Compatible with the existing model
  • - Various cradle type : E, F and G type
  • - Control voltage
    • · DC 24~30V, DC 48~60V, DC 110V, DC 125V, DC 220V
    • · AC 48V, AC 100~130V, AC 220~250V
  • - Accessories
    • · Closing spring contact , UVT, Secondary trip coil, Current trip coil, Trip Latch Checking S/W(Ready to Close S/W), Position S/W
    • · Key lock, Button lock, Button cover Padlock, UVT Time Delay Controller, Lifting hook, CTD
  • - Draw in/out indication
  • - Standard and certification
    • · IEC 62271-100(2008.04) [M2, C2, E2(List1)]
    • · Type tested in an Enclosure
    • · Type tested by KERI

Characteristics

Characteristics

Low duty

  • - Rated short time : 3 sec
  • - Operation sequence : O-0.3s-CO-15s-CO
  • - Mechanical endurance : M2
  • - Electrical endurance : E (List 1)
  • - Capacitive current breaking capacity : C2
  • - Mechanical / Electrical life cycle (time) : 30,000
  • - Cradle : Fixed type, E type, F type, G type
  • - Control voltage : DC 24~30V, DC 48~60V, DC 110V, DC 125V, DC 220V, AC 48V, AC 100~130V, AC 220~250V

Mid duty

  • - Rated short time : 3 sec
  • - Operation sequence : O-0.3s-CO-15s-CO
  • - Mechanical endurance : M2
  • - Electrical endurance : E2 (List 3)
  • - Capacitive current breaking capacity : C2
  • - Mechanical / Electrical life cycle (time) : 30,000
  • - Cradle : Fixed type, E type, F type, G type, H type
  • - CB Compartment (Box type cradle) for MCSG
  • - Control voltage : DC 24~30V, DC 48~60V, DC 110V, DC 125V, DC 220V,AC 48V, AC 100~130V, AC 220~250V

High duty

  • - Rated short time : 3 sec
  • - Operation sequence : O-0.3s-CO-3min-CO
  • - Mechanical endurance : M2
  • - Electrical endurance : E2 (List 3)
  • - Capacitive current breaking capacity : C2
  • - Mechanical / Electrical life cycle (time) : 20,000
  • - Cradle : Fixed type, K type, H type
  • - CB Compartment (Box type cradle) for MCSG
  • - Control voltage : DC 48V, DC 110V, DC 125V, DC 220V, AC 48V, AC 110V, AC 220V

Ratings

Ratings

Low duty

Low duty
Ur(kV) Isc(kA) Ir(A)
7.2 8 400
12.5 630

Mid duty

Mid duty
Ur(kV) Isc(kA) Ir(A)
7.2 20 630
1250
2000
25 630
1250
2000
12 20 630
1250
2000
25 630
1250
2000
17.5 20 630
1250
2000
25 630
1250
2000

High duty

High duty
Ur(kV) Isc(kA) Ir(A)
7.2
12
17.5
50 1250
2000
2500
3150
4000
12 25 2500
31.5 1250
2000
3150
40 1250
2000
3150
36 25 1250
2000
3150
31.5 1250
2000
3150
40 1250
2000
3150
40.5 25 1250
2000
3150
31.5 1250
2000
3150

Download

検索
  • Catalog

    太陽光 発電用 電力系統ソリューション

    2017.11.13 Japanese 27MB

    太陽光 発電用 電力系統ソリューション

    CAD

    [VCB]Pro-MEC VCB CAD DATA

    2011.02.25 English 14MB

    Pro-MEC VCB 7.2kV 1. Draw-out type -VCB LVB-06E,F,G-20D,25D,32D,40D E,F,G-(630,1250,2000A) LVB-06E-32D,40D E(Visible_Tulip)-(3150A) LVB-06G-32D,40D G(Visible_Tulip)-(3150A) 2. Cradle - E Class LCL-06E-20D,25D E(Visible,Clip) LCL-06E-32D,40D E(Visible,Tulip) LCL-06E-32D,40D E(Visible,Tulip)-(3150A) 3. Cradle - F2 Class LCL-06F-20D,25D F(Visible,Clip)-(630,1250A) LCL-06F-32D,40D F(Visible_Tulip)_(1250,2000A) LCL-06F-32D,40D F(Visible_Tulip)_(3150A) 4. Cradle - G Class LCL-06G-20D,25D,32D,40D G(Visible,Clip) LCL-06G-20D(T),25D(T),32D(T),40D(T) G(Enclosed_Tulip)-(630,1250,2000A) LCL-06G-32D,40D G(Visible_Tulip)_(3150A) 5. Fixed type-VCB LVB-06P-20D,25D,32D,40D(Visible_ Fixed)-(630,1250,2000A) LVB-06P-32D,40D (Visible, Fixed)-(3150A) Pro-MEC VCB 12kV 6. Draw-out type - VCB LVB-12G-25D(T),32D(T) G 7. Cradle - G Class 12kV_LCL-12G-25D(T),32D(T) G (Enclo,Tulip) Pro-MEC VCB 17.5kV 8. Draw-out type - VCB vcb17.5_e&f_assy_630_1250_2000a vcb17.5_e&f_assy_2500a vcb17.5_g_assy_630_1250_2000a vcb17.5_g_assy_2500a 9. Cradle E Class F2 Class G Class 10. Fixed type - VCB vcb17.5_p_assy_630_1250_2000a vcb17.5_p_assy_2500a Pro-MEC VCB 24kV 11. Draw-out type - VCB 12. Cradle E Class F2 Class G Class 13. Fixed type - VCB

  • CAD

    [VCB] Susol VCB CAD DATA (eng.)

    2011.02.18 English 56MB

    [VCB] Susol VCB CAD DATA (eng.) VL 06 7.2kV 8/12.5kA 400/630A VL 06...17 7.2/12/17.5kV 20/25kA 630/1250/2000A VL 06...36 7.2/12/17.5kV 50kA 1250/2000/2500/3150/4000A 24kV 25kA 2500A, 31.5/40kA 1250/2000/3150 36kV 25/31.5/40kA 1250/2000/3150

    Catalog

    [VCB]Pro-MEC VCB Catalog (eng.)

    2011.02.15 English 9MB

    [VCB]Pro-MEC VCB Catalog

  • Catalog

    [VCB]Susol Vacuum Circuit Breakers technical maual(Russian)

    2011.01.04 Korean 15MB

    Catalog

    [VCB]Susol Vacuum Circuit Breakers for New Clear Power Plants catalog

    2010.11.17 English 1MB

top